ReceiverPdu
ReceiverPdu is a networked PDU information node.
Inheritance
Code
XML encoding
<ReceiverPdu whichGeometry='1' readInterval='0.1' writeInterval='1.0' networkMode='standAlone' isStandAlone='' isNetworkReader='' isNetworkWriter='' siteID='0' applicationID='1' entityID='0' address='localhost' port='0' multicastRelayHost='' multicastRelayPort='0' rtpHeaderExpected='false' isRtpHeaderHeard='' isActive='' timestamp='' radioID='0' receivedPower='0.0' receiverState='0' transmitterSiteID='0' transmitterApplicationID='0' transmitterEntityID='0' transmitterRadioID='0' bboxCenter='0 0 0' bboxSize='-1 -1 -1' render='TRUE' showBBox='FALSE' logFeature='' />
Classic encoding
ReceiverPdu {
whichGeometry 1
readInterval 0.1
writeInterval 1.0
networkMode standAlone
isStandAlone
isNetworkReader
isNetworkWriter
siteID 0
applicationID 1
entityID 0
address "localhost"
port 0
multicastRelayHost ""
multicastRelayPort 0
rtpHeaderExpected false
isRtpHeaderHeard
isActive
timestamp
radioID 0
receivedPower 0.0
receiverState 0
transmitterSiteID 0
transmitterApplicationID 0
transmitterEntityID 0
transmitterRadioID 0
bboxCenter 0 0 0
bboxSize -1 -1 -1
render TRUE
showBBox FALSE
logFeature [""]
}
Interface
Filter: X3D only | Avalon only | All
| id | Name | DataType | PartType | Default | ValueType | Description |
|---|---|---|---|---|---|---|
| whichGeometry | SFInt32 | initializeOnly | 1 | Select geometry to render: -1 for no geometry, 0 for text trace, 1 for default geometry. | ||
| readInterval | SFTime | initializeOnly | 0.1 | Seconds between read updates, 0 means no reading. | ||
| writeInterval | SFTime | initializeOnly | 1.0 | Seconds between write updates, 0 means no writing. | ||
| networkMode | SFFloat | initializeOnly | standAlone | Whether this entity is ignoring the network, sending DIS packets to the network, or receiving DIS packets from the network. (1) standAlone: ignore network but still respond to events in local scene. (2) networkReader: listen to network and read PDU packets at readInterval, act as remote copy of entity. (3) networkWriter: send PDU packets to network at writeInterval, act as master entity. Default value quotestandAlonequote ensures that DIS network activation within a scene as networkReader or networkWriter is intentional. | ||
| isStandAlone | SFBool | initializeOnly | Whether networkMode=quotelocalquote (ignore network but still respond to local events) | |||
| isNetworkReader | SFBool | initializeOnly | Whether networkMode=quoteremotequote (listen to network as copy of remote entity) | |||
| isNetworkWriter | SFBool | initializeOnly | Whether networkMode=quotemasterquote (output to network as master entity at writeInterval) | |||
| siteID | SFInt32 | initializeOnly | 0 | EntityID site. | ||
| applicationID | SFInt32 | initializeOnly | 1 | EntityID application ID, unique for application at that site. | ||
| entityID | SFInt32 | initializeOnly | 0 | EntityID unique ID for entity within that application. | ||
| address | SFString | initializeOnly | localhost | Multicast address, or else quotelocalhostquote Example: 224.2.181.145. | ||
| port | SFInt32 | initializeOnly | 0 | Multicast port example: 62040. | ||
| multicastRelayHost | SFString | initializeOnly | Fallback server address if multicast not available locally example: devo.cs.nps.navy.mil. | |||
| multicastRelayPort | SFInt32 | initializeOnly | 0 | Fallback server port if multicast not available locally example: 8010. | ||
| rtpHeaderExpected | SFBool | initializeOnly | false | Whether RTP headers are prepended to DIS PDUs. | ||
| isRtpHeaderHeard | SFBool | initializeOnly | Whether incoming DIS packets have an RTP header prepended. | |||
| isActive | SFBool | initializeOnly | Have we had a network update recently?. | |||
| timestamp | SFTime | initializeOnly | DIS timestamp in VRML units. | |||
| radioID | SFInt32 | initializeOnly | 0 | Identifies a particular radio within a given entity (entityID). The radioID is assigned sequentially, starting with 1. | ||
| receivedPower | SFFloat | initializeOnly | 0.0 | Indicates the RF power received, after applying any propagation loss and antenna gain. The field value is in units of decibel-milliwatts (dBm). | ||
| receiverState | SFInt32 | initializeOnly | 0 | Indicates if the receiver is currently idle or busy via one of the following enumerated values: 0 = off; 1 = on but not receiving; 2 = on and receiving. | ||
| transmitterSiteID | SFInt32 | initializeOnly | 0 | Provides the unique DIS site identifier for the transmitter entity. | ||
| transmitterApplicationID | SFInt32 | initializeOnly | 0 | Provides the application identifier for the transmitter entity that is unique within the DIS site (transmitterSiteID). | ||
| transmitterEntityID | SFInt32 | initializeOnly | 0 | Identifies the transmitter entity that has emitted the signal being received. | ||
| transmitterRadioID | SFInt32 | initializeOnly | 0 | Identifies the particular radio within the transmitter entity (transmitterEntityID). | ||
| bboxCenter | SFVec3f | initializeOnly | 0 0 0 | Bounding box center: position offset from origin of local coordinate system. | ||
| bboxSize | SFVec3f | initializeOnly | -1 -1 -1 | Bounding box size: automatically calculated, can be specified as an optimization or constraint. | ||
| render | SFBool | inputOutput | TRUE | Flag to control the visibility of the node or subtree | ||
| showBBox | SFBool | inputOutput | FALSE | Show Bounding Box of Subtree. | ||
| logFeature | MFString | inputOutput | state, child, parent, route, eventIn, eventOut | controls the logging of changes, state: log state changes (e.g. live), child: log child add/remove, parent: log parent add/remove, route: log route add/remove; eventIn: log receiving of events, eventOut: log sending of events: guiView, runtime system should create node-view, guiEdit: runtime system should create node-editeverything: log everything | ||
| metadata | SFNode | inputOutput | MetadataObject | container for payload metadata inside MetadataSet element |